Product description
Main technical parameters of 10KV KBSG series dry type mining explosion isolation mobable transformer substation
Main technical parameters of 6KV KBSG series dry type mining explosion isolation mobable transformer substation
Our service
1.quick response in before sales period help you got order.
2.excellent service in production time let you know each step we made.
3.reliable quality solve you after sale headache.
4.long period quality warranty ensure you can buy without hesitate.
2.1, For transformer whose rated capacity is 500 KVA and below, the load loss value above the slash in the table is suitable for Dyn11 or Yzn11 connection groups, and that below the slash for YynO connection groups.
2.2, Transformers whose HV tapping range is ±2×2.5 may be provided, if need be.
2.3, Transformers whose LV is 0.69KV may be provided, if need be.
2.4, Users may choose other loss values as they need.
2.5, Due to product upgrading and changes to the external dimensions and products in the table, please refer to the external dimensions provided at the time of ordering.
Attention
Our company



Our exhibition


Main technical parameters of 10KV KBSG series dry type mining explosion isolation mobable transformer substation
Rated capacity | voltage combination | connection method | Loss | No-load current | Impedance voltage | Weight | Outline dimension | Gauge vertical/horizontal | ||
High-voltage | low-voltage | No-load | load | |||||||
50 | 10±5% | 0.693/0.4 1.2/0.693 1.2 3.45 | Yy0(d11) | 390 | 680 | 2.5 | 4 | 1450 | 2250*800*1010 | 600 |
100 | 560 | 1050 | 2.5 | 1830 | 2400*845*1160 | 600 | ||||
200 | 950 | 1800 | 2 | 2360 | 2540*875*1400 | 600 | ||||
250 | 1100 | 2100 | 2 | 2760 | 2620*900*1435 | 600 | ||||
315 | 1300 | 2500 | 1.8 | 2950 | 2650*915*1505 | 600 | ||||
400 | 1500 | 3000 | 1.8 | 3350 | 2710*950*1520 | 600 | ||||
500 | 1750 | 3500 | 1.5 | 3620 | 2770*950*1535 | 600 | ||||
630 | 2000 | 4100 | 1.5 | 4500 | 2850*970*1660 | 600 | ||||
800 | Yy0(d11) Dyn11 | 2300 | 5100 | 1.2 | 5580 | 2910*1060*1615 | 600 | |||
1000 | 2600 | 6100 | 1.2 | 4.5 | 6450 | 3075*1050*1750 | 900 | |||
1250 | 3100 | 7400 | 1.0 | 4.5 | 6900 | 3145*1050*1790 | 900 | |||
1600 | 3800 | 8500 | 1.0 | 5 | 8430 | 3160*1220*1885 | 900 | |||
2000 | 4500 | 9700 | 0.7 | 5 | 11030 | 3665*1220*1900 | 900 | |||
2500 | 5200 | 10800 | 0.7 | 5.5 | 14080 | 3780*1390*1900 | 900 | |||
3150 | 6100 | 12800 | 0.7 | 5.5 | 18800 | 3880*1400*1900 | 900 | |||
4000 | 7000 | 15000 | 0.7 | 6 | 21600 | 4210*1460*1900 | 900 |
Main technical parameters of 6KV KBSG series dry type mining explosion isolation mobable transformer substation
Rated capacity | voltage combination | connection method | Loss | No-load current | Impedance voltage | Weight | Outline dimension | Gauge vertical/horizontal | ||
High-voltage | low-voltage | No-load | load | |||||||
50 | 6±5% | 0.693/0.4 1.2/0.693 1.2 3.45 | Yy0(d11) | 350 | 550 | 2.5 | 4 | 1350 | 2150*780*910 | 600 |
100 | 520 | 920 | 2.5 | 1480 | 2200*800*1100 | 600 | ||||
200 | 820 | 1550 | 2 | 1980 | 2450*835*1285 | 600 | ||||
250 | 950 | 1800 | 2 | 2670 | 2550*885*1325 | 600 | ||||
315 | 1100 | 2150 | 1.8 | 2850 | 2585*885*1340 | 600 | ||||
400 | 1300 | 2600 | 1.8 | 3050 | 2700*895*1450 | 600 | ||||
500 | 1500 | 3100 | 1.5 | 3590 | 2750*945*1475 | 600 | ||||
630 | 1800 | 3680 | 1.5 | 3860 | 2770*960*1535 | 600 | ||||
800 | Yy0(d11) Dyn11 | 2050 | 4500 | 1.0 | 4975 | 2770*990*1600 | 600 | |||
1000 | 2350 | 5400 | 1.0 | 5900 | 2930*1060*1615 | 900 | ||||
1250 | 2750 | 6500 | 1.0 | 6860 | 2965*1010*1640 | 900 | ||||
1600 | 3350 | 8000 | 0.8 | 8480 | 3010*1175*1760 | 900 | ||||
2000 | 3800 | 9500 | 0.6 | 4.5 | 9180 | 3225*1220*1790 | 900 | |||
2500 | 4500 | 10600 | 0.6 | 5 | 13080 | 3580*1230*1850 | 900 | |||
3150 | 5300 | 12500 | 0.6 | 5.5 | 16500 | 3820*1260*1890 | 900 | |||
4000 | 6100 | 14000 | 0.6 | 6 | 19060 | 3930*1400*1890 | 900 |
Our service
1.quick response in before sales period help you got order.
2.excellent service in production time let you know each step we made.
3.reliable quality solve you after sale headache.
4.long period quality warranty ensure you can buy without hesitate.
2.1, For transformer whose rated capacity is 500 KVA and below, the load loss value above the slash in the table is suitable for Dyn11 or Yzn11 connection groups, and that below the slash for YynO connection groups.
2.2, Transformers whose HV tapping range is ±2×2.5 may be provided, if need be.
2.3, Transformers whose LV is 0.69KV may be provided, if need be.
2.4, Users may choose other loss values as they need.
2.5, Due to product upgrading and changes to the external dimensions and products in the table, please refer to the external dimensions provided at the time of ordering.
Attention
The payment term | We accept TT,30% deposit and Pay 70% before shipment. |
The delivery time | Usually it will take about 15-20 days. |
package | Usually use wooden for protection. |
Our company



Our exhibition